-<WRAP hide>====== Laminar flow hood</WRAP> +<wrap lo>« Air can be described as a sea of invisible micro-organismsthat directly contaminate sterilized media once exposedAirborne contaminants enter a petri dish at the time the lid is opened; during pouringinoculation or incubation »</wrap>[(:ref:stamets_ggm)]
-<WRAP info>The plans presented below have required many hours of workand some expensive trials and errorsIf you find they were useful for youa [[https://www.paypal.com/cgi-bin/webscr?cmd=_s-xclick&hosted_button_id=6HLVNSG9CPQYJ|financial contribution]], regardless of the amount, would be greatly appreciated.+
  
-Please note that like all the unreferenced information on this wiki, this content is __only__ available __under the terms of the license__ [[http://creativecommons.org/licenses/by-nc-sa/3.0/|Creative Commons BY-NC-SA 3.0]].</WRAP>+<tab>
  
 +====== Laminar flow hood ======
 +The flow hood is a sterile air blower. The particles of the air are separated by a pre-filter and a HEPA filter. This results in almost pure air, separated at 99.97% from particles greater than 0.3 µm. This clean air exerts a positive pressure on the work plan, allowing to easily produce axenic cultures.
 ====== Prototype 1 & 2 ====== ====== Prototype 1 & 2 ======
 The first prototype met the expectations, but several details deserved to be improved. The plans, drawings and the budget of the second version are available below. The first prototype met the expectations, but several details deserved to be improved. The plans, drawings and the budget of the second version are available below.
Line 145: Line 146:
 |Fan (Fasco™ A1200 + bracket)|  1  |  450  |  **450**  | |Front doors|  2  |  ?  |  **?**  | |Fan (Fasco™ A1200 + bracket)|  1  |  450  |  **450**  | |Front doors|  2  |  ?  |  **?**  |
 |HEPA Filter (18"x24"x6”)|  1  |  175  |  **175**  | |Glass work area (24"x23"x¼”)|  1  |  30  |  **30**  | |HEPA Filter (18"x24"x6”)|  1  |  175  |  **175**  | |Glass work area (24"x23"x¼”)|  1  |  30  |  **30**  |
-|Pre-filters (9 ¾"x19 ¾")|  2  |  5.75  |  **11.5**  | |Glass shelves (4 ½"x12"x1/8")|  2  |  7  |  **14**  |+|Pre-filters (9 ¾"x19 ¾")|  2  |  5.75  |  **11.5**  | |Glass shelves (4 ½"x12"")|  2  |  7  |  **14**  |
 |3-positions switch (115V, 15A)|  1  |  6  |  **6**  | |Glass shelf clips[(:hidden:>{{:fr:construction:glass_clip.jpg?100|}})]|  4  |  3.5  |  **14**  | |3-positions switch (115V, 15A)|  1  |  6  |  **6**  | |Glass shelf clips[(:hidden:>{{:fr:construction:glass_clip.jpg?100|}})]|  4  |  3.5  |  **14**  |
 |Power cord (115V, 15A)|  1  |  10  |  **10**  | | | | ^  **58**  | |Power cord (115V, 15A)|  1  |  10  |  **10**  | | | | ^  **58**  |